Hello,

We have hit a wall while developing CAM5/6 to carry more tracers and diagnose the radiative forcing. The maximum number of lines availiable in mode_defs in the namelist is 65. We need to extend this to be able to carry out our simulations and hoping someone can point to where this value has been set in the code?

Many thanks in advance for any help,

Douglas Hamilton

 

eaton

Look in rad_constituents.F90 for the parameter n_mode_str and change there.  It might also be necessary to go into the file bld/namelist_files/namelist_definition.xml and change the definition for mode_defs so that the type attribute matches the declaration in rad_constituents.

 

dsh224@...

Great! Thanks for the quick reply, very much appreciated.

 